作者/來(lái)源:徐廣平(山東陽(yáng)煤恒通化工股份有限公司,山東 郯城 276100) 日期: 2012-03-29 點(diǎn)擊率:2541
摘 要:通過(guò)分析與試驗(yàn),發(fā)現(xiàn)造氣爐夾套失效的原因是由于空程尺寸過(guò)大。
關(guān)鍵詞:造氣爐夾套;失效;空程尺寸
中圖分類號(hào):TQ113.25 文獻(xiàn)標(biāo)志碼:B 文章編號(hào):1003-6490(2011)05-0026-02
Analysis of Failure Reasons of Water Lined jacket in Fixed-Bed Gasifiers
XU Guang-ping
(Shandong Yangmei Hengtong Chemical Co.,Ltd., Tancheng Shandong 276100,China)
Abstract:After analysis and experiment, failure reasons of the water lined jacket in fixed-bed gasifier is due to the air space oversized.
Key words:water lined jacket in fixed-bed gasifier;failure;air space size
1 存在的問(wèn)題
山東陽(yáng)煤恒通化工股份有限公司化肥廠2009....